JE Heat Pump

High performance, energy efficient pool/spa heating.

The Jandy Pro Series JE Series line of premium heat pumps delivers maximum energy efficiency and reliability.

Find a Dealer

Description

High performance, energy efficient pool/spa heating.

The Jandy Pro Series JE Series line of premium pool heat pumps delivers maximum energy efficiency and reliability. Working efficiently, JE pool heat pumps absorb free heat from the air and transfer it to the water, making the heating process ecological and cost-effective.

Features

  • Ultra-Efficient - Featuring a premium titanium heat exchanger, JE Series heat pumps provide superior hydraulic flow for maximum energy savings
  • Superior Control - Easy-to-operate dual thermostats (pool/spa)
  • User-Friendly - Features advanced digital control to enable self diagnostics, multilingual capability, and an auto-heat feature, when used in conjunction with Aqualink® control systems, to maintain your pool’s temperature automatically and efficiently 24 hours per day
  • Versa Plumb®-Ready - All JE Heat Pumps are Versa Plumb®-ready, allowing you to achieve up to 50% more hydraulic efficiency for maximum energy savings

Technical Details

  • Proprietary ultra efficient titanium heat exchanger
  • AquaLink® automation-ready digital control
  • Easy to operate Dual Thermostats (Pool/Spa)
  • Versa Plumb® - Ready
  • Optional chiller/hot gas defrost (Available on 3000 models)
  • Four standard models available are JE1500 (70,000 BTU), JE2000 (96,000 BTU), JE2500 (110,000 BTU), and JE3000 (132,000 BTU). 3-Phase models available are JE2500 and JE3000. An ultra-premium model featuring optional chiller mode is also available: JE3000 (130,000 BTU).
  • Includes 2/2.5" unions
  • Environmentally-friendly (410A refrigerant)

Specifications

Feature JE1500T JE2000T JE2500T JE2500T3 JE3000T JE3000TR JE3000T3 JE3000TR3
Voltage 230V / 60Hz 230V / 60Hz 230V / 60Hz 208 / 230V / 60Hz / 3 230V / 60Hz 230V / 60Hz 208 / 230V / 60Hz / 3 208 / 230V / 60Hz / 3
Output (80/80/80)* 70,000 BTUs 96,000 BTUs 110,000 BTUs 110,000 BTUs 132,000 BTUs 130,000 BTUs 132,000 BTUs 132,000 BTUs
Input (80/80/80)* 3.83 kW 5.03 kW 5.34 kW 5.34 kW 6.34 kW 6.34 kW 6.34 kW 6.34 kW
COP (80/80/80)* 5.4 5.8 5.8 5.8 6.1 6.0 6.1 6.0
Output (80/63/80)** 67,000 BTUs 92,000 BTUs 106,000 BTUs 106,000 BTUs 127,000 BTUs 127,000 BTUs 127,000 BTUs 127,000 BTUs
COP (80/63/80)** 5.2 5.7 5.6 5.6 6.0 5.9 6.0 5.9
Output (50/63/80)** 46,000 BTUs 64,000 BTUs 74,000 BTUs 74,000 BTUs 86,000 BTUs 86,000 BTUs 86,000 BTUs 86,000 BTUs
COP (50/63/80)*** 4.0 4.0 4.0 4.0 4.2 4.0 4.2 4.0
RLA (Running load amps)
23.72 30.77 32.05 23.21 32.05 32.05 25.00 25.00
LRA (Locked rotor amps) 153 178 148 164 185 185 164 164
Minimum Circuit Ampacity 31.65 40.21 41.81 30.76 41.81 41.81 33.00 33.00
Max Over Current Protection**** 50 60 60 45 60 60 50 50
Compressor Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
Heat Exchanger Titanium Tube-in-Tube Titanium High Flow Titanium High Flow Titanium High Flow Titanium High Flow Titanium High Flow Titanium High Flow Titanium High Flow
Optimal Water Flow 30 GPM 42 GPM 48 GPM 48 GPM 57 GPM 57 GPM 57 GPM 57 GPM
Minimum Water Flow 20 GPM 20 GPM 20 GPM 20 GPM 20 GPM 20 GPM 20 GPM 20 GPM
Maximum Water Flow 70 GPM 70 GPM 70 GPM 70 GPM 70 GPM 70 GPM 70 GPM 70 GPM
Weight 175 lbs 220 lbs 223 lbs 223 lbs 228 lbs 230 lbs 228 lbs 230 lbs
Cabinet ABS ABS ABS ABS ABS ABS ABS ABS
Refrigerant 52 OZ, R410A 78 OZ, R410A 78 OZ, R410A 78 OZ, R410A 118 OZ, R410A 126 OZ, R410A 118 OZ, R410A 126 OZ, R410A
Refrigerant High Pressure Alarm 600 PSI (reset to 445 PSI) 600 PSI (reset to 445 PSI) 600 PSI (reset to 445 PSI) 600 PSI (reset to 445 PSI) 600 PSI (reset to 445 PSI) 600 PSI (reset to 445 PSI) 600 PSI (reset to 445 PSI) 600 PSI (reset to 445 PSI)
Refrigerant Low Pressure Alarm - Heating Units 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI)
Refrigerant Low Pressure Alarm - Reverse Units 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI) 35 PSI (reset to 60 PSI)
Low Water Flow Alarm 20 GPM 20 GPM 20 GPM 20 GPM 20 GPM 20 GPM 20 GPM 20 GPM
Maximum Height Below Water Level 10 feet below water level 10 feet below water level 10 feet below water level 10 feet below water level 10 feet below water level 10 feet below water level 10 feet below water level 10 feet below water level
Maximum Height Above Water Level 5 feet above water level 5 feet above water level 5 feet above water level 5 feet above water level 5 feet above water level 5 feet above water level 5 feet above water level 5 feet above water level
Optimal Water Flow 30 GPM 42 GPM 48 GPM 48 GPM 57 GPM 57 GPM 57 GPM 57 GPM
Maximum Water Flow 70 GPM 70 GPM 70 GPM 70 GPM 70 GPM 70 GPM 70 GPM 70 GPM
Air Flow 2100 CFM 3600 CFM 3600 CFM 3600 CFM 3600 CFM 3600 CFM 3600 CFM 3600 CFM
Water Temperature Differential (Delta T) Adjustable 1°F - 5°F Adjustable 1°F - 5°F Adjustable 1°F - 5°F Adjustable 1°F - 5°F Adjustable 1°F - 5°F Adjustable 1°F - 5°F Adjustable 1°F - 5°F Adjustable 1°F - 5°F
Union Size 2 by 2.5" 2 by 2.5" 2 by 2.5" 2 by 2.5" 2 by 2.5" 2 by 2.5" 2 by 2.5" 2 by 2.5"

* Rated in accordance with AHRI Standard 1160; Test Conditions: 80*F Air, 80% RH, 80*F Water
** Rated in accordance with AHRI Standard 1160; Test Conditions: 80*F Air, 63% RH, 80*F Water
*** Rated in accordance with AHRI Standard 1160; Test Conditions: 50*F Air, 63% RH, 80*F Water
**** Max Over Current Protection refers to the maximum breaker size allowed. If this value is not a standard breaker size, use the next smallest standard breaker size. The breaker size must not be smaller than the Minimum Circuit Ampacity value

Models

Models Description
JE1500T HEAT PUMP ASSEMBLY, 230V/60HZ, 1-PHASE, JANDY INTERFACE
JE2000T HEAT PUMP ASSEMBLY, 230V/60HZ, 1-PHASE, JANDY INTERFACE
JE2500T HEAT PUMP ASSEMBLY, 230V/60HZ, 1-PHASE, JANDY INTERFACE
JE2500T3 HEAT PUMP ASSEMBLY, 208/230V/60HZ, 3-PHASE, JANDY INTERFACE
JE3000T HEAT PUMP ASSEMBLY, 230V/60HZ, 1-PHASE, JANDY INTERFACE
JE3000T3 HEAT PUMP ASSEMBLY, 208/230V/60HZ, 3-PHASE, JANDY INTERFACE
JE3000TR HEAT PUMP ASSY, REVERSE (HEAT/COOL), 230V/60HZ, 1-PHASE, JANDY INTERFACE
JE3000TR3 HEAT PUMP ASSEMBLY, REVERSE (HEAT/COOL), 208/230V/60HZ, 3-PHASE, JANDY INTERFACE

Parts Breakout Diagram

Heat Pumps JE Series Heat Pump Parts

Launch our online catalog viewer to review breakout diagrams and part numbers.

Learn More

Resources

JE Series Heat Pump Brochure

Item #: SL6407
File Size: 2804265
Language: EN

Download View Online
JE3000T Heat Pump Brochure

Item #: SL6408
File Size: 1994092
Language: EN

Download View Online
JE Series Heat Pump Owner's Installation Manual

Item #: H0408600
File Size: 8073960
Language: EN

Download View Online
JE Heat Pump Anchor Bracket Instructions

Item #: H0424400
File Size: 363466
Language: EN

Download View Online

Protect your warranty!

Professional Installation Required

Pro Resources

Log in to your Zodiac Rewards account now to get access to pro resources.

Log in Now