Stealth™ Pump

Quiet, Powerful, Efficient

The Stealth is a professional-grade pump that combines superior performance with energy-saving efficiency and "Quiet Technology," making it the most efficient single- and...

Find a Dealer

partner_v_c

ENERGY STAR® certified models highlighted in blue below.

Quiet, Powerful, Efficient

The Stealth is a professional-grade pump that combines superior performance with energy-saving efficiency and “Quiet Technology,” making it the most efficient single- and two-speed pump available. The Stealth is easy to install, and contains the largest trap basket on the market for easy routine maintenance.

Features

  • "E+ Energy-Efficient" motor saves up to 20 percent on energy costs
  • Features the largest trap basket on the market for reduced maintenance
  • Ergonomic handles and easy-to-read indicators
  • "Quiet Technology" design controls flow dynamics within pump, resulting in less noise
  • .5, .75, 1.0, 1.5, 2.0, 2.5, 3.0, 5.0 HP Models available.

Technical Details

  • Largest capacity basket in the industry fully maximizes hydraulic flow
  • 2"x2½" (2½" x3" on 3 and 5 HP model) quick-connect unions
  • .5, .75, 1.0, 1.5, 2.0, 2.5, 3.0, and 5.0 HP models available

Specifications

Full Rated Pumps

Model HP Voltage Amps Pipe Size Carton Weight Overall Length ‘A’
SHPF.50 .50 208–230/115 4.4–4.5/8.0 2"-2.5" 30 lbs 31"
SHPF.75 .75 208–230/115 6.0–5.6/11.2 2"-2.5" 43 lbs 31"
SHPF1.0 1.0 208–230/115 7.8–7.4/14.8 2"-2.5" 45 lbs 32.25"
SHPF1.5 1.5 208–230 9.6–8.8 2"-2.5" 50 lbs 32"
SHPF2.0 2.0 208–230 11.0–10.0 2"-2.5" 57 lbs 33"
SHPF3.0 3.0 208–230 15.0–13.6 2.5"-3.0" 62 lbs 33"
SHPF5.0 5.0 208–230 17.0–19.0 4" 68 lbs 33"
SHPF1.0-2 1.0 230 7.2/3.0 2"-2.5" 50.4 lbs 33"
SHPF1.5-2 1.5 230 10.0/3.5 2"-2.5" 57 lbs 33"
SHPF2.0-2 2.0 230 11.0/4.0 2"-2.5" 64 lbs 33"

3 Phase Pumps

Model HP Voltage Amps Pipe Size Carton Weight Overall Length ‘A’
SHPF1.0-3PH 1.0 208–230/460 5.0–4.6/2.3 2"-2.5" 55 lbs 31"
SHPF1.5-3PH 1.5 208–230/460 6.4–5.8/2.9 2"-2.5" 57 lbs 32"
SHPF2.0-3PH 2.0 208–230/460 7.1– 6.8/3.4 2"-2.5" 64 lbs 32"
SHPF3.0-3PH 3.0 208–230/460 9.0–8.6/4.3 2.5"-3" 62 lbs 32"

Maximum (Up) Rated Pumps

Model HP Voltage Amps Pipe Size Carton Weight Overall Length ‘A’
SHPM.75 .75 208–230/115 4.4–4.5/8.8 2"-2.5" 30 lbs 33"
SHPM1.0 1.0 208–230/115 6.0–5.6/11.2 2"-2.5" 43 lbs 31"
SHPM1.5 1.5 208–230/115 7.8–7.4/14.8 2"-2.5" 45 lbs 32.25"
SHPM2.0 2.0 208–230 9.6–8.8 2"-2.5" 50 lbs 32"
SHPM2.5 2.5 208–230 11.0–10.0 2"-2.5" 57 lbs 33"
SHPM1.5-2 1.5 230 7.2/3.0 2"-2.5" 52 lbs 33"
SHPM2.0-2 2.0 230 10.0/3.5 2"-2.5" 57 lbs 32"
SHPM2.5-2 2.5 230 11.0/4.0 2"-2.5" 64 lbs 33"

Models

Models Description
SHPF1.0-2 Jandy Pro Series Stealth High Head Pump, 230 VAC, Full-Rated1.0 HP
SHPF1.5-2 Jandy Pro Series Stealth High Head Pump, 230 VAC, Full-Rated 1.5 HP
SHPF2.0-2 Jandy Pro Series Stealth High Head Pump, 230VAC, Full-Rated 2.0 HP, 2-Speed
SHPM1.5-2 Jandy Pro Series Stealth High Head Pump, 230VAC, Up-rated 1.5HP 2-Speed
SHPM2.0-2 Jandy Pro Series Stealth High Head Pump, 230VAC, Up-rated 2.0 HP, 2-Speed
SHPM2.5-2 Jandy Pro Series Stealth High Head Pump, 230 V AC, Up-rated 2.5 HP, 2-Speed
SHPF1.0 Jandy Pro Series Stealth High Head Pump, 208-230/115 VAC, Full-Rated, 1.0 HP
SHPF1.0-3PH Jandy Pro Series Stealth High Head Pump, 208/230/460 VAC, Full-Rated, 1.0 HP, 3 Phase, 60 Hz
SHPF1.5 Jandy Pro Series Stealth High Head Pump, 208-230/115 VAC, Full-Rated, 1.5 HP
SHPF1.5-3PH Jandy Pro Series Stealth High Head Pump, 208/230/460 VAC, Full-Rated, 1.5 HP, 3 Phase, 60Hz
SHPF2.0 Jandy Pro Series Stealth High Head Pump, 208-230 VAC, Full-Rated 2.0HP
SHPF3.0 Jandy Pro Series Stealth High Head Pump, 208-230 VAC, Full-Rated3.0HP
SHPF3.0-3PH Jandy Pro Series Stealth High Head Pump, 208/230/460 VAC, Full-Rated, 3.0 HP, 3 Phase, 60 Hz
SHPF5.0 Jandy Pro Series Stealth High Head Pump, 208-230 VAC, Full-Rated 5.0HP
SHPF.50 Jandy Pro Series Stealth High Head Pump, 208-230/115 VAC, Full-Rated, 0.50 HP
SHPF.75 Jandy Pro Series Stealth High Head Pump, 208-230/115 VAC, Full-Rated. 0.75 HP
SHPM1.0 Jandy Pro Series Stealth High Head Pump, 208-230/115 VAC, Up-Rated, 1.0 HP
SHPM1.5 Jandy Pro Series Stealth High Head Pump, 208-230/115 VAC, Up-Rated, 1.5HP
SHPM2.0 Jandy Pro Series Stealth High Head Pump, 208-230 VAC, Up-rated 2.0HP
SHPM2.5 Jandy Pro Series Stealth High Head Pump, 208-230 VAC, Up-rated 2.5HP
SHPM.75 Jandy Pro Series Stealth High Head Pump, 208-230/115 VAC, Up-Rated, 0.75HP

Parts Breakout Diagram

Jandy Pumps by Zodiac

Stealth Pump Parts List

Launch our online catalog viewer to review breakout diagrams and part numbers.

Learn More

Accessories

Models Description  
SEAQL1001 Jandy Pro Series Sweep Elblow Aqualink Temp
SEFL1002 Jandy Pro Series Sweep Elbow Flowlink

Frequently Asked Questions

Click to open a frequently asked question and answer.

Air leaks are still present.

1 Check the suction side piping union. While the pump is running, try to tighten the union. If this does not stop the air leak, turn off the pump. Loosen both unions and slide the pump out of the way. Remove, clean and re-install both union o-rings.
2. Reposition the pump next to the piping and secure the union nuts to the pump. With clean union o-rings, hand tightening of the unions should create a seal. If the unions still do not seal, gently tighten with a large pair of tongue and groove pliers. DO NOT OVER-TIGHTEN.

Bubbles present in the pump basket.

1. Air in system. Check the pool or spa water level to ensure it is at the proper level and that air is not being drawn into the suction plumbing.
2. If the water is at normal level, turn off the pump. Remove the lid and check for debris around the lid o-ring seat, as this will cause air leaks in the system.
3. Clean the lid o-ring and put the lid back in place.
4. Hand tighten the lid to make an air tight seal.
5. Do not use any tools to tighten the lid. Turn the pump back on.

The cleaning/circulating system is not operating correctly.


1. Verify that the skimmer baskets, pump basket and other screens are clean. Clean as necessary.
2. Check filter and clean as necessary.
3. Check valve positions. Adjust as necessary. Note: Multiple pieces of equipment operating at one time (for example, waterfalls, spa jets, and surface returns) will affect the cleaning system and may prevent it from working properly.
4. Check the cleaning system manual to ensure that the system is adjusted according to the manufacturer's recommendations.

The pump gets hot and shuts off periodically.

1. Ensure that there is adequate room around the motor to circulate air and keep the motor cool.
2. Have a qualified electrician check for loose connections and check the voltage at the pump motor while it is in operation. The voltage must be within 10% of the motors data plate rating. If the voltage is not within 10%, contact a qualified electrician and/or the local power service provider.

The pump is leaking water between the motor and pump body.

This is caused by a damaged or failed mechanical seal. Replace the seal. See the "Mechanical Seal Replacement" portion of the manual.

There is no air in the system, but the pressure is still low.

1. It is possible that debris is caught in the impeller. The pump impeller moves the water, and the vanes in the impeller can become blocked with debris. See the "Blocked Impeller" portion of your manual for more information.

There is no debris blocking the impeller and the pressure is still low.

1. The pump impeller and diffuser are showing signs of normal wear. Have a qualified service technician check the impeller and diffuser and replace as necessary.
2. If the pump is part of a relatively new instalaltion, it could be an electrical problem. Contact a qualified service technician. Have the technician check for loose electrical connections and check the voltage at the pump motor while in operation. The voltage must be within 10% of the motor's data plate rating. If the vltage is not within 10%, contact a qualified electrician and/or the local power service provider.
3. Pump seal is leaking air. Have a qualified service technician replace the seal.

Will I lose water if I run my pool pump on Bypass?

No, you only lose water in a pool if there is a leak, through splash out, and when you backwash.

Resources

Jandy Stealth Pump Sell Sheet

Item #: SL6204
File Size: 6961925
Language: EN

Download View Online

Zodiac Pumps Family Brochure (EN)

Item #: SL6200
File Size: 4085043
Language: EN

Download View Online

Jandy Stealth Pump Specification Sheet

Item #: SA6222
File Size: 484375
Language: EN

Download View Online

Stealth Series Pump I/O Manual

Item #: H0573800
File Size: 2514300
Language: EN

Download View Online

Stealth Pump Body Replacement Kit Instructions

Item #: H0280400
File Size: 245175
Language: EN

Download View Online

Stealth Pump Body Replacement Kit Instructions

Item #: H0576700
File Size: 1182642
Language: EN

Download View Online

Protect your warranty!

Professional Installation Required

Pro Resources

Log in to your Zodiac Premium® account now to get access to pro resources.

Log in Now