PlusHP

High Performance in a Compact Body

PlusHP pumps deliver the high performance of a larger pump in a compact body, making it the best choice for pool and spa renovations, in-floor cleaning systems, spa-jet...

Find a Dealer

partner_v_c

ENERGY STAR® certified models highlighted in blue below.

High Performance in a Compact Body

PlusHP pumps deliver the high performance of a larger pump in a compact body, making it the best choice for pool and spa renovations, in-floor cleaning systems, spa-jet boosters, solar energy heating systems, and small equipment areas.

Features

  • Available in highly efficient two-speed models, which can save up to 60% on electrical consumption compared to single-speed pumps
  • Designed with Jandy® Pro Series' Quiet Technology for whisper-quiet operation
  • Larger trap basket for greater debris holding capacity

Technical Details

  • Powerful, efficient, compact high-head pump
  • Large trap basket for increased debris-holding capacity
  • Ergonomic Cam-Lock Lid with easy-to-read aligning indicators
  • Comes complete with 2" x 2 ½" quick-connect unions
  • Ideal for in-floor cleaning, spa-jet boosters, and solar systems
    • H: 14 1/8"
    • W: 9 1/8"
    • L: 28 ¾" – 30 ¾"
  • Available in .5, .75, 1.0, 1.5, 2.0, 2.5 HP models

Specifications

Full Rated Pumps

Model HP Voltage Amps Pipe Size Carton Weight Overall Length ‘A’
PHPF.50 .50 230/115 5.4/10.8 1.5"-2" 40.4 lbs 28.75"
PHPF.75 .75 230/115 7.1/14.2 2"-2.5" 41.8 lbs 28.75"
PHPF1.0 1.0 230-115 8.0/16.0 2"-2.5" 43.3 lbs 29.25"
PHPF1.5 1.5 230/115 11.2/22.4 2"-2.5" 54.6 lbs 30.75"
PHPF2.0 2.0 230 11.5 2"-2.5" 49.3 lbs 29"
PHPF1.0-2 1.0 230 7.2/3.0 2"-2.5" 48.7 lbs 29.75"
PHPF1.5-2 1.5 230 10.0/3.5 2"-2.5" 52.9 lbs 30.25"
PHPF2.0-2 2.0 230 11.0/4.0 2"-2.5" 62.3 lbs 29.75"

Maximum (Up) Rated Pumps

Model HP Voltage Amps Pipe Size Carton Weight Overall Length ‘A’
PHPM.75 .75 230/115 5.4/10.8 1.5"-2" 40.4 lbs 28.75"
PHPM1.0 1.0 230/115 7.1/14.2 2"-2.5" 41.8 lbs 28.75"
PHPM1.5 1.5 230/115 8.0/16.0 2"-2.5" 43.3 lbs 29.25"
PHPM2.0 2.0 230/115 11.2/22.4 2.5"-3" 54.6 lbs 30.75"
PHPM2.5 2.5 230 11.5 2"-2.5" 49.3 lbs 29"
PHPM1.5-2 1.5 230 7.2/3.0 2"-2.5" 48.7 lbs 29.75"
PHPM2.0-2 2.0 230 10.0/3.5 2"-2.5" 59.9 lbs 30.25"
PHPM2.5-2 2.5 230 11.0/4.0 2"-2.5" 62.3 lbs 29.75"

Models

Models Description
PHPF.50 Jandy Pro Series PlusHP High Head Pump, 230/115 VAC, .Full-Rated 50HP
PHPF.75 Jandy Pro Series PlusHP High Head Pump, 230/115 VAC, .Full-Rated 75HP
PHPF1.0 Jandy Pro Series PlusHP High Head Pump, 230/115 VAC, Full-Rated 1.0HP
PHPF1.5 Jandy Pro Series PlusHP High Head Pump, 230/115 VAC, Full-Rated 1.5HP
PHPF2.0 Jandy Pro Series PlusHP High Head Pump, 230 VAC,Full-Rated 2.0HP
PHPF1.0-2 Jandy Pro Series PlusHP High Head Pump, 230 VAC ,Full-Rated 1.0 HP, 2-Speed
PHPF1.5-2 Jandy Pro Series PlusHP High Head Pump, 230 VAC, Full-Rated1.5 HP, 2-Speed
PHPF2.0-2 Jandy Pro Series PlusHP High Head Pump, 230 VAC ,Full-Rated 2.0 HP, 2-Speed
PHPM.75 Jandy Pro Series PlusHP High Head Pump, 230/115 VAC, .Up-rated 75HP
PHPM1.0 Jandy Pro Series PlusHP High Head Pump, 230/115 VAC, Up-rated 1.0HP
PHPM1.5 Jandy Pro Series PlusHP High Head Pump, 230/115 VAC, Up-rated 1.5HP
PHPM2.0 Jandy Pro Series PlusHP High Head Pump, 230/115 VAC, Up-rated 2.0HP
PHPM2.5 Jandy Pro Series PlusHP High Head Pump, 230 VAC, Up-rated 2.5HP
PHPM1.5-2 Jandy Pro Series PlusHP High Head Pump, 230 VAC, Up-rated 1.5HP 2Speed
PHPU2.0-2 Jandy High Head Pump, 230 VAC, 2.0 HP, 2 Speed
PHPM2.5-2 Jandy Pro Series PlusHP High Head Pump, 230 VAC, Up-rated 2.0 HP, 2-Speed

Parts Breakout Diagram

Jandy Pumps by Zodiac

PlusHP Pump Parts List

Launch our online catalog viewer to review breakout diagrams and part numbers.

Learn More

Accessories

Models Description  
SEAQL1001 Jandy Pro Series Sweep Elblow Aqualink Temp
SEFL1002 Jandy Pro Series Sweep Elbow Flowlink

Frequently Asked Questions

Click to open a frequently asked question and answer.

Air leaks are still present.

1 Check the suction side piping union. While the pump is running, try to tighten the union. If this does not stop the air leak, turn off the pump. Loosen both unions and slide the pump out of the way. Remove, clean and re-install both union o-rings.
2. Reposition the pump next to the piping and secure the union nuts to the pump. With clean union o-rings, hand tightening of the unions should create a seal. If the unions still do not seal, gently tighten with a large pair of tongue and groove pliers. DO NOT OVER-TIGHTEN.

Bubbles present in the pump basket.

1. Air in system. Check the pool or spa water level to ensure it is at the proper level and that air is not being drawn into the suction plumbing.
2. If the water is at normal level, turn off the pump. Remove the lid and check for debris around the lid o-ring seat, as this will cause air leaks in the system.
3. Clean the lid o-ring and put the lid back in place.
4. Hand tighten the lid to make an air tight seal.
5. Do not use any tools to tighten the lid. Turn the pump back on.

The cleaning/circulating system is not operating correctly.


1. Verify that the skimmer baskets, pump basket and other screens are clean. Clean as necessary.
2. Check filter and clean as necessary.
3. Check valve positions. Adjust as necessary. Note: Multiple pieces of equipment operating at one time (for example, waterfalls, spa jets, and surface returns) will affect the cleaning system and may prevent it from working properly.
4. Check the cleaning system manual to ensure that the system is adjusted according to the manufacturer's recommendations.

The pump gets hot and shuts off periodically.

1. Ensure that there is adequate room around the motor to circulate air and keep the motor cool.
2. Have a qualified electrician check for loose connections and check the voltage at the pump motor while it is in operation. The voltage must be within 10% of the motors data plate rating. If the voltage is not within 10%, contact a qualified electrician and/or the local power service provider.

The pump is leaking water between the motor and pump body.

This is caused by a damaged or failed mechanical seal. Replace the seal. See the "Mechanical Seal Replacement" portion of the manual.

There is no air in the system, but the pressure is still low.

1. It is possible that debris is caught in the impeller. The pump impeller moves the water, and the vanes in the impeller can become blocked with debris. See the "Blocked Impeller" portion of your manual for more information.

There is no debris blocking the impeller and the pressure is still low.

1. The pump impeller and diffuser are showing signs of normal wear. Have a qualified service technician check the impeller and diffuser and replace as necessary.
2. If the pump is part of a relatively new instalaltion, it could be an electrical problem. Contact a qualified service technician. Have the technician check for loose electrical connections and check the voltage at the pump motor while in operation. The voltage must be within 10% of the motor's data plate rating. If the vltage is not within 10%, contact a qualified electrician and/or the local power service provider.
3. Pump seal is leaking air. Have a qualified service technician replace the seal.

Will I lose water if I run my pool pump on Bypass?

No, you only lose water in a pool if there is a leak, through splash out, and when you backwash.

Resources

Jandy Plus HP Pump Sell Sheet

Item #: SL6202
File Size: 5956197
Language: EN

Download View Online

Zodiac Pumps Family Brochure (EN)

Item #: SL6200
File Size: 4085043
Language: EN

Download View Online

Jandy PlusHP Specification Sheet

Item #: SA6221
File Size: 438506
Language: EN

Download View Online

Zodiac PlusHP Series Pumps I/O Manual

Item #: H0279500
File Size: 2330507
Language: EN

Download View Online

Protect your warranty!

Professional Installation Required

Pro Resources

Log in to your Zodiac Premium® account now to get access to pro resources.

Log in Now