FloPro™

Compact, Versatile, Powerful

FloPro pumps have an innovative adjustable base, allowing for trouble-free installation on new construction or quick and easy replacement of existing pumps.

Find a Dealer

partner_v_c

ENERGY STAR® certified models highlighted in blue below.

Compact, Versatile, Powerful

FloPro pumps have an innovative adjustable base, allowing for trouble-free installation on new construction or quick and easy replacement of existing pumps. With the FloPro, minimal plumbing adjustments are required, thereby enabling cost-effective pump replacement.

Features

  • Medium-head, high-flow pump in an ultra-compact body. Excellent choice for tight equipment areas
  • Energy-efficient 2-speed models provide uncompromising power to filter and recirculate pool and spa water while keeping costs down
  • Quiet operation
  • Innovative inline connectivity helps eliminate unsightly pipes and plumbing

Technical Details

  • Medium-head, high-flow pump in an ultra-compact body
  • Adjustable base options allow for easy replacement of select Hayward®, Pentair®, Sta-Rite®, and Jandy® pumps
  • Ergonomic cam-lock lid with easy alignment indicators
  • Equipped with 2" pump unions and 2" internal threads
  • .75, 1.0, 1.5, 2.0, 2.5 HP models available

Specifications

Model HP Voltage Amps Pipe Size Carton Weight Overall Length 'A'
FHPM .75 0.75 230/115 5.4/10.8 2"-2.5" 40.6 lbs 25 3/16"
FHPM 1.0 1.0 230/115 7.1/14.2 2"-2.5" 41.2 lbs 25 3/16"
FHPM 1.5 1.5 230-115 8.0/16.0 2"-2.5" 42.6 lbs 25 1/2"
FHPM 2.0 2.0 230/115 11.2/22.4 2"-2.5" 54.6 lbs 27 3/16"
FHPM 2.5 2.5 230 11.5 2"-2.5" 48.6 lbs 26 3/16"
FHPM 1.0-2SPD 1.0 230 7.1/2.3 2"-2.5" 46.5 lbs 26 5/16"
FHPM 1.5-2SPD 1.5 230 8.0/3.0 2"-2.5" 48.0 lbs 26 9/16"
FHPM 2.0-2SPD 2.0 230 11.2/3.5 2"-2.5" 52.9 lbs 27 11/16"

Models

Models Description
FHPM1.0 Jandy Pro Series FloPro Medium Head Pump, 230/115 VAC,1.0HP US US
FHPM1.5 Jandy Pro Series FloPro Medium Head Pump, 230/115 VAC, 1.5HP US
FHPM2.0 Jandy Pro Series FloPro Medium Head Pump, 230/115 VAC, 2.0HP US
FHPM2.5 Jandy Pro Series FloPro Medium Head Pump, 230/VAC, 2.5HP US
FHPM.75 Jandy Pro Series FloPro Medium Head Pump, 230/115 VAC, .75HP US
FHPM1.0-2 Jandy Pro Series FloPro Medium Head Pump,230/1 15 VAC,1.0HP, 2-Speed US
FHPM1.5-2 Jandy Pro Series FloPro Medium Head Pump, 230/115 VAC, 1.5HP, 2-Speed US
FHPM2.0-2 Jandy Pro Series FloPro Medium Head Pump, 230/115 VAC, 2.0HP, 2-Speed US

Parts Breakout Diagram

Jandy Pumps by Zodiac

FloPro Pump Parts List

Launch our online catalog viewer to review breakout diagrams and part numbers.

Learn More

Accessories

Models Description  
SEAQL1001 Jandy Pro Series Sweep Elblow Aqualink Temp
SEFL1002 Jandy Pro Series Sweep Elbow Flowlink

Frequently Asked Questions

Click a frequently asked question below to see the answer.

Air leaks are still present.

1 Check the suction side piping union. While the pump is running, try to tighten the union. If this does not stop the air leak, turn off the pump. Loosen both unions and slide the pump out of the way. Remove, clean and re-install both union o-rings.
2. Reposition the pump next to the piping and secure the union nuts to the pump. With clean union o-rings, hand tightening of the unions should create a seal. If the unions still do not seal, gently tighten with a large pair of tongue and groove pliers. DO NOT OVER-TIGHTEN.

Bubbles present in the pump basket.

1. Air in system. Check the pool or spa water level to ensure it is at the proper level and that air is not being drawn into the suction plumbing.
2. If the water is at normal level, turn off the pump. Remove the lid and check for debris around the lid o-ring seat, as this will cause air leaks in the system.
3. Clean the lid o-ring and put the lid back in place.
4. Hand tighten the lid to make an air tight seal.
5. Do not use any tools to tighten the lid. Turn the pump back on.

The cleaning/circulating system is not operating correctly.


1. Verify that the skimmer baskets, pump basket and other screens are clean. Clean as necessary.
2. Check filter and clean as necessary.
3. Check valve positions. Adjust as necessary. Note: Multiple pieces of equipment operating at one time (for example, waterfalls, spa jets, and surface returns) will affect the cleaning system and may prevent it from working properly.
4. Check the cleaning system manual to ensure that the system is adjusted according to the manufacturer's recommendations.

The pump gets hot and shuts off periodically.

1. Ensure that there is adequate room around the motor to circulate air and keep the motor cool.
2. Have a qualified electrician check for loose connections and check the voltage at the pump motor while it is in operation. The voltage must be within 10% of the motors data plate rating. If the voltage is not within 10%, contact a qualified electrician and/or the local power service provider.

The pump is leaking water between the motor and pump body.

This is caused by a damaged or failed mechanical seal. Replace the seal. See the "Mechanical Seal Replacement" portion of the manual.

There is no air in the system, but the pressure is still low.

1. It is possible that debris is caught in the impeller. The pump impeller moves the water, and the vanes in the impeller can become blocked with debris. See the "Blocked Impeller" portion of your manual for more information.

There is no debris blocking the impeller and the pressure is still low.

1. The pump impeller and diffuser are showing signs of normal wear. Have a qualified service technician check the impeller and diffuser and replace as necessary.
2. If the pump is part of a relatively new installation, it could be an electrical problem. Contact a qualified service technician. Have the technician check for loose electrical connections and check the voltage at the pump motor while in operation. The voltage must be within 10% of the motor's data plate rating. If the voltage is not within 10%, contact a qualified electrician and/or the local power service provider.
3. Pump seal is leaking air. Have a qualified service technician replace the seal.

Will I lose water if I run my pool pump on Bypass?

No, you only lose water in a pool if there is a leak, through splash out, and when you backwash.

Resources

Jandy Pro Series FloPro Pump Sell Sheet (EN)

Item #: SL6206
File Size: 2157191
Language: EN

Download View Online

Zodiac Pumps Family Brochure (EN)

Item #: SL6200
File Size: 4085043
Language: EN

Download View Online

Jandy FloPro Specification Sheet

Item #: SA6220
File Size: 1165496
Language: EN

Download View Online

FloPro Series Pump I/O Manual

Item #: H0315300
File Size: 2721442
Language: EN

Download View Online

FloPro Parts Replacement Kit Instructions

Item #: H0318300
File Size: 2798701
Language: EN

Download View Online

FloPro Pump Body Replacement Kit Instructions

Item #: H0318400
File Size: 1787571
Language: EN

Download View Online

Protect your warranty!

Professional Installation Required

Pro Resources

Log in to your Zodiac Premium® account now to get access to pro resources.

Log in Now